Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: KSOM0
Old ISKO number: 1414
Locality: Sokolov
Type of measuring programme: Heavy metal in PM10
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ-pob. Ústí n. Labem
Pošt.přihrádka 2
40011 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas
Cover
sampler (situated separately)
Note
Sídliště na JV okraji města v rohu školního pozemku částečně otevřené, v okolí vysoké panelové domy, ve svahu. Odběr : 24hod, analýza kovů každý 5.den.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 55 PM₁₀ [particles PM10] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GRV [gravimetry] - Yes No 0 Y A A A R A 1d/2d 2020-01-01
L1 D2 55 V [vanadium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N A A A R A 1d/2d 2020-01-01
L1 D2 55 Cr [chromium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N A A A R A 1d/2d 2020-01-01
L1 D2 55 Mn [manganese] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 N A A A R A 1d/2d 2020-01-01
L1 D2 55 Fe [iron] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N A A R A 1d/2d 2020-01-01
L1 D2 55 Co [cobalt] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N A A R A 1d/2d 2020-01-01
L1 D2 55 Ni [nickel] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y A A A R A 1d/2d 2020-01-01
L1 D2 55 Cu [copper] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 N A A A R A 1d/2d 2020-01-01
L1 D2 55 Zn [zinc] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N A A A R A 1d/2d 2020-01-01
L1 D2 55 As [arsenic] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y A A A R A 1d/2d 2020-01-01
L1 D2 55 Se [selenium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N A A R A 1d/2d 2020-01-01
L1 D2 55 Cd [cadmium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y A A A R A 1d/2d 2020-01-01
L1 D2 55 Pb [lead] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y A A A R A 1d/2d 2020-01-01
L1 D3 12 PM₁₀ [particles PM10] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GRV [gravimetry] - Yes No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D1 8 PM₁₀ [particles PM10] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GRV [gravimetry] - Yes No 0 Y N N N N N 1d/2d 2005-01-01 2015-12-31
L1 D3 12 V [vanadium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2003-12-30
L1 D3 8 V [vanadium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/2d 2011-01-01 2015-12-31
L1 D3 12 Cr [chromium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 Cr [chromium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/2d 2011-01-01 2015-12-31
L1 D3 12 Mn [manganese] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 Mn [manganese] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 N N N N N N 1d/2d 2005-01-01 2015-12-31
L1 D3 12 Fe [iron] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 Fe [iron] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/2d 2011-01-01 2015-12-31
L1 D3 8 Co [cobalt] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/2d 2011-01-01 2015-12-31
L1 D3 12 Ni [nickel] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 Ni [nickel] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y N N N N N 1d/2d 2005-01-01 2015-12-31
L1 D3 12 Cu [copper] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 Cu [copper] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 N N N N N N 1d/2d 2005-01-01 2015-12-31
L1 D3 8 Zn [zinc] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/2d 2011-01-01 2015-12-31
L1 D3 12 As [arsenic] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 As [arsenic] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y N N N N N 1d/2d 2005-01-01 2015-12-31
L1 D3 12 Se [selenium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 Se [selenium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/2d 2011-01-01 2015-12-31
L1 D3 12 Cd [cadmium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 Cd [cadmium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y N N N N N 1d/2d 2005-01-01 2015-12-31
L1 D3 12 Sb [antimony] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-30
L1 D3 12 Pb [lead] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
L1 D3 8 Pb [lead] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y N N N N N 1d/2d 2005-01-01 2015-12-31
L1 D3 12 Pb208/206 [isotopic ratio 208 Pb/206 Pb] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2003-12-30
L1 D3 12 Pb207/206 [isotopic ratio 207 Pb/206Pb] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N N N N N 1d/5d 1996-01-05 2003-12-30
List of laboratories
Laboratory number 1 (L1) ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 (D1) CHMI-CLI TK
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 484
 
E-mail: lucie.sedlakova@chmi.cz
Supplier number 2 (D2)
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 488
 
E-mail: eliska.svobodova@chmi.cz
Supplier number 3 (D3) ČHMÚ-CLI TK
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 482
 
E-mail: stepan.rychlik@chmi.cz