Information about air quality in the Czech Republic
Measuring programme table
Updated: 2024-10-23 04:52 CEST
Basic data | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | KSOM0 | |||||||||||||||||
Old ISKO number: | 1414 | |||||||||||||||||
Locality: | Sokolov | |||||||||||||||||
Type of measuring programme: | Heavy metal in PM10 | |||||||||||||||||
Measuring networks: | National air pollution monitoring network | |||||||||||||||||
Administrator | ||||||||||||||||||
ČHMÚ-pob. Ústí n. Labem
Pošt.přihrádka 2 40011 Ústí nad Labem |
Tel.: 472 706 053 | |||||||||||||||||
E-mail: petr.goll@chmi.cz | ||||||||||||||||||
Target of the measuring programme | ||||||||||||||||||
Evalution of concentration in urban areas | ||||||||||||||||||
Cover | ||||||||||||||||||
sampler (situated separately) | ||||||||||||||||||
Note | ||||||||||||||||||
Sídliště na JV okraji města v rohu školního pozemku částečně otevřené, v okolí vysoké panelové domy, ve svahu. Odběr : 24hod, analýza kovů každý 5.den. | ||||||||||||||||||
Measurements | ||||||||||||||||||
Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | 55 | PM₁₀ [particles PM10] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | GRV [gravimetry] | - | Yes | No | 0 | Y | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | V [vanadium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Cr [chromium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Mn [manganese] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | N | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Fe [iron] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Co [cobalt] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Ni [nickel] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | Y | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Cu [copper] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | N | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Zn [zinc] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | As [arsenic] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | Y | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Se [selenium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Cd [cadmium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | Y | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D2 | 55 | Pb [lead] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | Y | A | A | A | R | A | 1d/2d | 2020-01-01 | |
L1 | D3 | 12 | PM₁₀ [particles PM10] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | GRV [gravimetry] | - | Yes | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D1 | 8 | PM₁₀ [particles PM10] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | GRV [gravimetry] | - | Yes | No | 0 | Y | N | N | N | N | N | 1d/2d | 2005-01-01 | 2015-12-31 |
L1 | D3 | 12 | V [vanadium] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2003-12-30 |
L1 | D3 | 8 | V [vanadium] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/2d | 2011-01-01 | 2015-12-31 |
L1 | D3 | 12 | Cr [chromium] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | Cr [chromium] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/2d | 2011-01-01 | 2015-12-31 |
L1 | D3 | 12 | Mn [manganese] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | Mn [manganese] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | N | N | N | N | N | N | 1d/2d | 2005-01-01 | 2015-12-31 |
L1 | D3 | 12 | Fe [iron] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | Fe [iron] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/2d | 2011-01-01 | 2015-12-31 |
L1 | D3 | 8 | Co [cobalt] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/2d | 2011-01-01 | 2015-12-31 |
L1 | D3 | 12 | Ni [nickel] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | Ni [nickel] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | Y | N | N | N | N | N | 1d/2d | 2005-01-01 | 2015-12-31 |
L1 | D3 | 12 | Cu [copper] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | Cu [copper] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | N | N | N | N | N | N | 1d/2d | 2005-01-01 | 2015-12-31 |
L1 | D3 | 8 | Zn [zinc] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/2d | 2011-01-01 | 2015-12-31 |
L1 | D3 | 12 | As [arsenic] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | As [arsenic] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | Y | N | N | N | N | N | 1d/2d | 2005-01-01 | 2015-12-31 |
L1 | D3 | 12 | Se [selenium] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | Se [selenium] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/2d | 2011-01-01 | 2015-12-31 |
L1 | D3 | 12 | Cd [cadmium] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | Cd [cadmium] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | Y | N | N | N | N | N | 1d/2d | 2005-01-01 | 2015-12-31 |
L1 | D3 | 12 | Sb [antimony] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-30 |
L1 | D3 | 12 | Pb [lead] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2004-12-31 |
L1 | D3 | 8 | Pb [lead] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | Yes | No | 0 | Y | N | N | N | N | N | 1d/2d | 2005-01-01 | 2015-12-31 |
L1 | D3 | 12 | Pb208/206 [isotopic ratio 208 Pb/206 Pb] | LVSman2.3 [LVS - manual filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2003-12-30 |
L1 | D3 | 12 | Pb207/206 [isotopic ratio 207 Pb/206Pb] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | - | No | No | 0 | N | N | N | N | N | N | 1d/5d | 1996-01-05 | 2003-12-30 |
List of laboratories | ||||||||||||||||||
Laboratory number 1 (L1) |
ČHMÚ-CLI TK
Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033451 | ||||||||||||||||
E-mail: stepan.rychlik@chmi.cz | ||||||||||||||||||
List of data suppliers | ||||||||||||||||||
Supplier number 1 (D1) |
CHMI-CLI TK
Generála Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244 033 484 | ||||||||||||||||
E-mail: lucie.sedlakova@chmi.cz | ||||||||||||||||||
Supplier number 2 (D2) |
Generála Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244 033 488 | ||||||||||||||||
E-mail: eliska.svobodova@chmi.cz | ||||||||||||||||||
Supplier number 3 (D3) |
ČHMÚ-CLI TK
Generála Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244 033 482 | ||||||||||||||||
E-mail: stepan.rychlik@chmi.cz |