Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-11 04:49 CEST


Basic data
Code: LLIMP
Old ISKO number: 1611
Locality: Liberec-mesto
Type of measuring programme: Measuring program of PAHs
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ-pob. Ústí n. Labem
Pošt.přihrádka 2
40011 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas
Cover
sampler (situated separately)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 10 BaA [benzo(a)anthracene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y N N N N N 1d/3d 2013-01-02 2015-07-08
L1 D1 10 Chry [chrysene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y N N N N N 1d/3d 2013-01-01 2015-07-08
L1 D1 10 BbF [benzo(b)fluoranthene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y N N N N N 1d/3d 2006-01-01 2015-07-08
L1 D1 10 BjF [benzo(j)fluoranthene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N N N N N 1d/3d 2013-07-01 2015-07-08
L1 D1 10 BkF [benzo(k)fluoranthene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y N N N N N 1d/3d 2006-01-01 2015-07-08
L1 D1 10 BbF_BkF [suma benzo(b)fluoranten a benzo(k)fluoranten] - GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N N N N N 1d/3d 2005-01-01 2005-12-31
L1 D1 10 B[𝑎]P [benzo[a]pyrene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y N N N N N 1d/3d 2005-01-01 2015-07-08
L1 D1 10 I123cdP [indeno(1,2,3,-cd) pyrene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y N N N N N 1d/3d 2005-01-01 2015-07-08
L1 D1 10 DBahA [dibenzo(a,h)anthracene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y N N N N N 1d/3d 2005-01-01 2015-07-08
L1 D1 10 BghiPRL [benzo(g,h,i) perylene] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y N N N N N 1d/3d 2005-01-01 2015-07-08
L1 D1 10 COR [coronen] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N N N N N 1d/3d 2009-01-01 2015-07-08
L1 D1 10 PAHs [polycyclic aromatic hydreocarbons -] - GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N N N N N 1d/3d 2005-01-01 2005-12-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ-pobočka Ústi n/Labem
Kočkovská 18
40011 Ústi n/Labem
Tel.: 472706050
 
E-mail: petra.mrazova@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ-pobočka Ústí n/Labem
Kočkovská 18
40011 Ústi nad Labem
Tel.: 472 706 050
 
E-mail: petra.mrazova@chmi.cz