Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: MPRRA
Old ISKO number: 1076
Locality: Prerov
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network , EUROAIRNET
Administrator
ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava - Poruba
Tel.: 596 900 218
 
E-mail: blanka.krejci@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Velmi dobrá otevřená lokalita v městském centru. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y A A A R A 10min 2004-01-01
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 25 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2015-06-11
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2004-01-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-09-30
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-09-30
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-09-30
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-09-30
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-09-30
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-09-30
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-09-30
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-09-30
L1 D1 97 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - Yes Yes 0 N N A N N N 1h 2004-07-20
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 1h 2005-01-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 10min 2005-01-31
L1 D1 97 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-07-20
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 1994-02-02 2003-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-02-02 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-02-02 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-02-02 2003-12-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - Yes No 0 N N N N N N 30min 1994-05-18 2003-12-31
L1 D1 22 O₃ [ozone] - UVABS [UV-absorption] - Yes No 0 N N N N N N 30min 2001-01-01 2003-12-31
L1 D1 26 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - No Yes 0 Y N N N N N 1h 2009-01-01 2011-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 1995-10-22 2003-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1994-02-02 1995-10-21
L1 D1 28 BZN [Benzene] - GC-FID [gas chromatography - flame-ionization detection] - Yes Yes 0 Y N N N N N 1h 2007-09-01 2012-12-31
L1 D1 28 TLN [toluene] - GC-FID [gas chromatography - flame-ionization detection] - Yes Yes 0 Y N N N N N 1h 2007-09-01 2012-12-31
L1 D1 28 EBZN [ethylbenzene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 Y N N N N N 1h 2007-09-01 2009-12-31
L1 D1 28 MPXY [m,p-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 Y N N N N N 1h 2007-09-01 2009-12-31
L1 D1 28 OXY [o-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 Y N N N N N 1h 2007-09-01 2009-12-31
L1 D1 38 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-07-20 2004-09-29
L1 D1 38 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-07-20 2004-09-28
L1 D1 38 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-07-20 2004-09-29
L1 D1 38 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-07-20 2004-09-28
L1 D1 38 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-07-20 2004-09-29
L1 D1 38 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-07-20 2004-09-29
L1 D1 38 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-07-20 2004-09-29
L1 D1 38 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-07-20 2004-09-29