Updated: 2025-01-16 03:44 CET
Basic data | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | PPLEA | |||||||||||||||||
Old ISKO number: | 1321 | |||||||||||||||||
Locality: | Plzen-stred | |||||||||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||||||||
Measuring networks: | EUROAIRNET | |||||||||||||||||
Administrator | ||||||||||||||||||
Správa infrastruktury města Plzně
Dominikánská 4 301 00 Plzeň |
Tel.: 378035136 | |||||||||||||||||
E-mail: | ||||||||||||||||||
Target of the measuring programme | ||||||||||||||||||
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS) | ||||||||||||||||||
Cover | ||||||||||||||||||
container (air-conditioned) | ||||||||||||||||||
Note | ||||||||||||||||||
V přízemním zděném objektu na rozhraní parku a historické zástavby. Odběrové sondy jsou umístěné na střeše objektu. | ||||||||||||||||||
Measurements | ||||||||||||||||||
Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | 93 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg∙m -3 | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
L1 | D1 | 93 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg∙m -3 | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-01-01 | |
L1 | D1 | 94 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg∙m -3 | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2004-01-01 | |
L1 | D1 | 94 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg∙m -3 | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2004-01-01 | |
L1 | D1 | 94 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg∙m -3 | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2004-01-01 | |
L1 | D1 | 88 | PM 1 [fine particles PM1] | - | OPEL [optoelectronic method] | µg∙m -3 | No | Yes | 0 | N | N | N | N | N | N | 1h | 2012-05-31 | |
L1 | D1 | 88 | PM₂.₅ [fine particles PM2.5] | - | OPEL [optoelectronic method] | µg∙m -3 | Yes | Yes | 0 | N | N | A | A | A | A | 1h | 2012-05-31 | |
L1 | D1 | 88 | PM₁₀ [particles PM10] | - | OPEL [optoelectronic method] | µg∙m -3 | Yes | Yes | 0 | N | N | A | A | A | A | 1h | 2012-06-01 | |
L1 | D1 | 41 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
L1 | D1 | 41 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
L1 | D1 | 17 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg∙m -3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-01 | 2003-12-31 |
L1 | D1 | 18 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg∙m -3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-01 | 2003-12-31 |
L1 | D1 | 18 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg∙m -3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-01 | 2003-12-31 |
L1 | D1 | 18 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg∙m -3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-01 | 2003-12-31 |
L1 | D1 | 20 | CO [carbon monoxide] | - | IRABS [IR corel. absorption spectrometry] | µg∙m -3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2017-08-22 |
L1 | D1 | 20 | CO [carbon monoxide] | - | IRABS [IR corel. absorption spectrometry] | µg∙m -3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-01 | 2003-12-31 |
L1 | D1 | 26 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg∙m -3 | No | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2012-05-31 |
L1 | D1 | 26 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg∙m -3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-01 | 2003-12-31 |
L1 | D1 | 41 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-01 | 2003-12-31 |
L1 | D1 | 41 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-01 | 2003-12-31 |
List of laboratories | ||||||||||||||||||
Laboratory number 1 (L1) |
ČHMÚ - pob. Plzeň
Mozartova 41 323 00 Plzeň |
Tel.: 377256641 | ||||||||||||||||
E-mail: tomas.fory@chmi.cz | ||||||||||||||||||
List of data suppliers | ||||||||||||||||||
Supplier number 1 (D1) |
ČHMÚ - pob. Plzeň
Mozartova 41 323 00 Plzeň |
Tel.: 377256641 | ||||||||||||||||
E-mail: tomas.fory@chmi.cz |