Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-11 04:49 CEST


Basic data
Code: PPLSA
Old ISKO number: 1325
Locality: Plzen-Skvrnany
Type of measuring programme: Automated measuring program
Measuring networks:
Administrator
Správa infrastruktury města Plzně
Dominikánská 4
301 00 Plzeň
Tel.: 378035136
 
E-mail:
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
V kontejneru na rozhraní zástavby sídlištního typu a volné krajiny s převažující ornou půdou. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2017-02-08
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 N N N N N N 10min 2004-01-01 2017-02-08
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2016-11-21
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2016-11-21
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2016-11-21
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 27 PM 1 [fine particles PM1] - OPEL [optoelectronic method] - Yes Yes 0 N N N N N N 1h 2012-05-16 2017-05-31
L1 D1 27 PM₂.₅ [fine particles PM2.5] - OPEL [optoelectronic method] - Yes Yes 0 N N N N N N 1h 2012-05-16 2017-05-31
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - No Yes 0 N N N N N N 1h 2004-01-01 2012-05-15
L1 D1 27 PM₁₀ [particles PM10] - OPEL [optoelectronic method] - Yes Yes 0 N N N N N N 1h 2012-05-16 2017-05-31
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 37 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2006-11-16
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-11-17 2017-05-31
L1 D1 37 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 37 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-01-01 2006-11-16
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-11-17 2017-05-31
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2006-11-16
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-11-17 2017-05-31
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-01-01 2006-11-16
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-11-17 2017-05-31
L1 D1 37 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2006-11-16
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2007-01-01 2017-05-31
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2015-01-01 2017-05-31
L1 D1 37 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2006-11-16
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2007-01-01 2017-05-31
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2015-01-01 2017-05-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - Yes Yes 0 N N A N N N 1h 2004-01-01 2016-12-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-01-01 2017-05-31
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
L1 D1 41 T10m [temperature 10m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-01-01 2017-05-31
L1 D1 41 T10m [temperature 10m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1996-09-01 2003-12-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz