Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: SKLMA
Old ISKO number: 1454
Locality: Kladno-stred mesta
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Stanice je umístěna v panelové zástavbě u parkoviště, asi 50m od stanice je komunikace se slabým provozem. PM10,PM2,5 - sondy Digitel DPM10, DPM2,5. 22.6.2004 došlo k výměně prachoměrů FH621R PM10 a PM2,5 se sondami Digitel za MP101M PM10-Digitel, PM2,5 sonda URG. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 25 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2004-01-01
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2004-01-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-07-16
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-07-16
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-07-16
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-07-16
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-07-16
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-07-16
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-07-16
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-07-16
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 10min 2004-01-01
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 1999-02-10 2003-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 10min 2004-10-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2015-03-23
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1999-02-10 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2015-03-23
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1999-02-10 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2015-03-23
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1999-02-10 2003-12-31
L1 D1 22 O₃ [ozone] - UVABS [UV-absorption] - Yes No 0 N N N N N N 30min 1999-03-05 2003-12-31
L1 D1 26 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 2003-03-01 2003-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 1999-02-10 2003-12-31
L1 D1 30 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 28 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] - Yes No 0 N N N N N N 30min 2003-10-21 2003-12-31
L1 D1 30 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 28 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] - Yes No 0 N N N N N N 30min 2003-10-21 2003-12-31
L1 D1 30 EBZN [ethylbenzene] - GC-PID [gas chromatography - photo-ionization detection] - Yes No 0 Y N N N N N 1h 2004-01-01 2009-12-31
L1 D1 28 EBZN [ethylbenzene] - GC-PID [gas chromatography - photo-ionization detection] - Yes No 0 N N N N N N 30min 2003-11-13 2003-12-31
L1 D1 30 MPXY [m,p-xylene] - GC-PID [gas chromatography - photo-ionization detection] - Yes No 0 Y N N N N N 1h 2004-01-01 2009-12-31
L1 D1 28 MPXY [m,p-xylene] - GC-PID [gas chromatography - photo-ionization detection] - Yes No 0 N N N N N N 30min 2003-10-21 2003-12-31
L1 D1 30 OXY [o-xylene] - GC-PID [gas chromatography - photo-ionization detection] - Yes No 0 Y N N N N N 1h 2004-01-01 2009-12-31
L1 D1 28 OXY [o-xylene] - GC-PID [gas chromatography - photo-ionization detection] - Yes No 0 N N N N N N 30min 2003-11-13 2003-12-31
L1 D1 37 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1999-04-08 2003-12-31
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1999-04-08 2003-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 1h 2004-01-01 2009-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 30min 2000-05-24 2003-12-31
L1 D1 0 T [temperature (unspecificated)] - PT100 [resistance method] - No No 0 N N N N N N 30min 1999-02-10 1999-08-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No No 0 N N N N N N 30min 2000-05-24 2003-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No No 0 N N N N N N 30min 2000-01-01 2003-12-31
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1999-04-08 2003-12-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ - Libuš AIM
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033467
 
E-mail: jan.silhavy@chmi.cz