Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-11 04:49 CEST


Basic data
Code: TMJSP
Old ISKO number: 2536
Locality: Mosty u Jablunkova-Šance
Type of measuring programme: Measuring program of PAHs
Measuring networks:
Administrator
ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava - Poruba
Tel.: 596 900 218
 
E-mail: blanka.krejci@chmi.cz
Target of the measuring programme
Cover
sampler (situated separately)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 12 BaA [benzo(a)anthracene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 Chry [chrysene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 BbF [benzo(b)fluoranthene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 BjF [benzo(j)fluoranthene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 BkF [benzo(k)fluoranthene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 BeP [benzo(e)pyren] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 B[𝑎]P [benzo[a]pyrene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 I123cdP [indeno(1,2,3,-cd) pyrene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 DBahA [dibenzo(a,h)anthracene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
L1 D1 12 BghiPRL [benzo(g,h,i) perylene] HVSauto30 [HVS -automatic filter change 30 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2023-01-01 2023-12-31
List of laboratories
Laboratory number 1 (L1) KHS-Ostrava
Partyzánské náměstí 7
702 00 Ostrava 1
Tel.: 596 200 361
 
E-mail: lucie.hellebrandova@zuova.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava-Poruba
Tel.: 596 900 239
 
E-mail: daniel.hladky@chmi.cz