Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: TOVKP
Old ISKO number: 2349
Locality: Opava-Katerinky
Type of measuring programme: Measuring program of PAHs
Measuring networks:
Administrator
ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava - Poruba
Tel.: 596 900 218
 
E-mail: blanka.krejci@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas
Cover
sampler (situated separately)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 55 BaA [benzo(a)anthracene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2020-01-01
L1 D1 55 Chry [chrysene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2020-01-01
L1 D1 55 BbF [benzo(b)fluoranthene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2020-01-01
L1 D1 55 BjF [benzo(j)fluoranthene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N A A A R A 1d/6d 2020-01-01
L1 D1 55 BkF [benzo(k)fluoranthene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2020-01-01
L1 D1 55 BeP [benzo(e)pyren] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N A A R A 1d/6d 2020-01-01
L1 D1 55 B[𝑎]P [benzo[a]pyrene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2020-01-01
L1 D1 55 I123cdP [indeno(1,2,3,-cd) pyrene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2020-01-01
L1 D1 55 DBahA [dibenzo(a,h)anthracene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2020-01-01
L1 D1 55 BghiPRL [benzo(g,h,i) perylene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 Y A A A R A 1d/6d 2020-01-01
L1 D1 55 COR [coronen] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N A A R A 1d/6d 2020-01-01
L1 D1 55 PIC [picene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N A A R A 1d/6d 2020-01-01
L1 D1 55 RET [retene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N A A R A 1d/6d 2022-01-03
L1 D1 55 PRL [perylene] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GC-MS [gas chromatography - mass spectroscopy (for PAH)] - Yes No 0 N N A A R A 1d/6d 2020-01-01
List of laboratories
Laboratory number 1 (L1) ČHMÚ-pobočka Ústi n/Labem
Kočkovská 18
40011 Ústi n/Labem
Tel.: 472706050
 
E-mail: petra.mrazova@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ-pobočka Ústí n/Labem
Kočkovská 18
40011 Ústi nad Labem
Tel.: 472 706 050
 