Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-09-11 04:50 CEST


Basic data
Code: TTRKA
Old ISKO number: 1187
Locality: Trinec-Kanada
Type of measuring programme: Automated measuring program
Measuring networks:
Administrator
MÚ-Třinec - Odbor ŽP a zem.
Jablunkovská 160
73961 Třinec
Tel.: 558306317
 
E-mail: anna.turonova@trinecko.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Stanice umístěna v obytné části města v zástavbě rodinných domků. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 88 PM 1 [fine particles PM1] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 1h 2016-10-01
L1 D1 88 PM₂.₅ [fine particles PM2.5] - OPEL [optoelectronic method] - Yes Yes 0 N N A A A A 1h 2016-10-01
L1 D1 88 PM₁₀ [particles PM10] - OPEL [optoelectronic method] - Yes Yes 0 N N A A A A 1h 2017-01-01
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 1h 2004-01-01
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 10min 2004-01-01
L1 D1 37 WD [wind direction] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 1h 2004-01-01
L1 D1 37 WD [wind direction] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 10min 2004-01-01
L1 D1 37 WVm [short-term wind velocity maximum] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 1h 2004-01-01
L1 D1 37 WVm [short-term wind velocity maximum] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 10min 2004-01-01
L1 D1 37 WDm [short-term wind direction maximum] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 1h 2004-01-01
L1 D1 37 WDm [short-term wind direction maximum] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 10min 2004-01-01
L1 D1 0 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No Yes 0 N N N N N N 1h 2017-10-12
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No Yes 0 N N N N N N 1h 2010-08-05
L1 D1 0 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No No 0 N N N N N N 1h 2004-01-01 2008-08-11
L1 D1 0 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No No 0 N N N N N N 30min 1994-01-01 1997-06-30
L1 D1 0 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No No 0 N N N N N N 30min 2002-01-09 2003-12-31
L1 D1 0 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No No 0 N N N N N N 10min 2004-01-01 2008-08-11
L1 D1 19 NO [nitrogen monoxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 1h 2004-01-01 2008-08-11
L1 D1 19 NO [nitrogen monoxide] - CHLM [chemiluminescence] - No Yes 0 N N A N R N 1h 2012-01-01 2023-12-31
L1 D1 19 NO [nitrogen monoxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1994-01-01 1997-06-30
L1 D1 19 NO [nitrogen monoxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 2002-01-09 2003-12-31
L1 D1 19 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 1h 2004-01-01 2008-08-11
L1 D1 19 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - No Yes 0 N N A N R N 1h 2012-01-01 2023-12-31
L1 D1 19 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1994-01-01 1997-06-30
L1 D1 19 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 2002-01-09 2003-12-31
L1 D1 19 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - No No 0 N N N N N N 1h 2004-01-01 2008-08-11
L1 D1 19 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - No Yes 0 N N A N R N 1h 2012-01-01 2023-12-31
L1 D1 19 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1994-01-01 1997-06-30
L1 D1 19 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 2002-01-09 2003-12-31
L1 D1 88 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - No Yes 0 N N N N N N 1h 2004-01-01 2016-12-31
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1997-03-06 1997-06-30
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 2002-01-09 2003-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1994-01-01 1997-03-05
L1 D1 73 BZN [Benzene] - GC-FID [gas chromatography - flame-ionization detection] - No Yes 0 N N N N N N 1h 2012-01-01 2017-12-31
L1 D1 73 TLN [toluene] - GC-FID [gas chromatography - flame-ionization detection] - No Yes 0 N N N N N N 1h 2012-01-01 2017-12-31
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No No 0 N N N N N N 30min 1994-01-01 1997-06-30
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No No 0 N N N N N N 30min 2002-01-09 2003-12-31
L1 D1 37 WD [wind direction] - ELMAG [electromagnetic method] - No No 0 N N N N N N 30min 1994-01-01 1997-06-30
L1 D1 37 WD [wind direction] - ELMAG [electromagnetic method] - No No 0 N N N N N N 30min 2002-01-09 2003-12-31
L1 D1 0 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 1h 2004-01-01 2008-03-29
L1 D1 0 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1996-04-01 1997-06-30
L1 D1 0 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 2002-01-09 2003-12-31
List of laboratories
Laboratory number 1 (L1) CHMI-brand Ostrava AIM
K Myslivně 3/2182
708 00 Ostrava - Poruba
Tel.: 596 900 228
 
E-mail: ooco_ova@chmi.cz
List of data suppliers
Supplier number 1 (D1) CHMI-brand Ostrava AIM
K Myslivně 3/2182
708 00 Ostrava-Poruba
Tel.: 596 900 239
 
E-mail: ooco_ova@chmi.cz