Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-07-15 08:09 CEST


Basic data
Code: TVERA
Old ISKO number: 1072
Locality: Vernovice-Dolni Lutyne
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET
Administrator
ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava - Poruba
Tel.: 596 900 218
 
E-mail: blanka.krejci@chmi.cz
Target of the measuring programme
Evalution of total level of concentrations beckground
Cover
container (air-conditioned)
Note
Velmi dobrá lokalita u hranic s Polskem, otevřená lokalita ve volné krajině (cca 500m od kraje obce). Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y A A A R A 1h 2005-01-01
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y A A A R A 10min 2005-01-01
L1 D1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2005-01-01
L1 D1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2005-01-01
L1 D1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2005-01-01
L1 D1 25 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2005-01-01
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2005-01-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2005-01-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2005-01-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2005-01-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2005-01-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2005-01-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2005-01-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2005-01-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2005-01-01
L1 D1 74 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2005-01-01
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 1994-07-22 2004-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-07-22 2004-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-07-22 2004-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-07-22 2004-12-31
L1 D1 26 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 2003-07-09 2004-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 1994-10-10 2004-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1994-07-22 1994-10-09
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 30min 2004-12-15 2004-12-31
L1 D1 38 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1995-01-01 2004-12-31
L1 D1 38 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1995-01-01 2004-12-31
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 30min 2004-12-01 2004-12-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No Yes 0 N N N N N N 1h 2010-07-02 2013-12-31
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1995-01-01 2004-12-31
List of laboratories
Laboratory number 1 (L1) CHMI-brand Ostrava AIM
K Myslivně 3/2182
708 00 Ostrava - Poruba
Tel.: 596 900 228
 
E-mail: ooco_ova@chmi.cz
List of data suppliers
Supplier number 1 (D1) CHMI-brand Ostrava AIM
K Myslivně 3/2182
708 00 Ostrava-Poruba
Tel.: 596 900 239
 
E-mail: ooco_ova@chmi.cz