Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: UMEDA
Old ISKO number: 1000
Locality: Medenec
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
Target of the measuring programme
Evalution of total level of concentrations beckground, Usage for operational management and regulation (SRVS), Evaluation of the effect on other environment components, damage evaluation
Cover
container (air-conditioned)
Note
Na samotě u rekreačního střediska (1.budova) v okolí pole, nízká zeleň, ve vrcholové partii, mírný svah. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y A A A R A 10min 2004-01-01
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2004-01-01
L1 D1 36 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2005-10-01
L1 D1 36 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2005-10-01
L1 D1 36 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2005-10-01
L1 D1 36 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2005-10-01
L1 D1 36 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2005-10-01
L1 D1 36 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2005-10-01
L1 D1 36 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2005-10-01
L1 D1 36 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2005-10-01
L1 D1 74 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 1992-03-04 2003-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1992-03-04 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1992-03-04 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1992-03-04 2003-12-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - Yes No 0 N N N N N N 30min 1995-03-23 2003-12-31
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 1995-10-21 2003-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1992-03-04 1995-10-20
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No No 0 N N N N N N 1h 2004-01-01 2005-09-30
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No No 0 N N N N N N 30min 1994-08-05 2003-12-31
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No No 0 N N N N N N 10min 2004-01-01 2005-09-30
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2005-09-30
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1994-08-05 2003-12-31
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-01-01 2005-09-30
L1 D1 37 WVm [short-term wind velocity maximum] - ELMAG [electromagnetic method] - No No 0 N N N N N N 1h 2004-01-01 2005-09-30
L1 D1 37 WVm [short-term wind velocity maximum] - ELMAG [electromagnetic method] - No No 0 N N N N N N 10min 2004-01-01 2005-09-30
L1 D1 37 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2005-09-30
L1 D1 37 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-01-01 2005-09-30
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No Yes 0 N N N N N N 1h 2004-01-01 2013-12-31
L1 D1 0 h [relative air humidity (h. of air)] - SKIN [animal skin] - No No 0 N N N N N N 30min 1994-08-05 1996-07-09
L1 D1 45 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No No 0 N N N N N N 30min 1996-07-10 2003-12-31
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1994-08-05 2003-12-31
List of laboratories
Laboratory number 1 (L1) CHMI-Usti n/L AIM
pošt. přihrádka 2
400 11 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2
40011 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz