Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-11-20 03:48 CET


Basic data
Code: URVHA
Old ISKO number: 1317
Locality: Rudolice v Horach
Type of measuring programme: Automated measuring program
Measuring networks: AMS-SRS, National air pollution monitoring network , EUROAIRNET
Administrator
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS), Evaluation of the highest air pollutant concentration in a given area
Cover
container (air-conditioned)
Note
Náhorní rovina, otevřená krajina, mimo obydlenou obec, travnatý povrch. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2004-01-01
L1 D1 36 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-07-01
L1 D1 36 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-07-01
L1 D1 36 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-07-01
L1 D1 36 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-07-01
L1 D1 36 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-07-01
L1 D1 36 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-07-01
L1 D1 36 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-07-01
L1 D1 36 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-07-01
L1 D1 97 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 10min 2004-01-01
L1 D1 97 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 1995-10-06 2003-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 10min 2004-01-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1995-10-06 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1995-10-06 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1995-10-06 2003-12-31
L1 D1 22 O₃ [ozone] - UVABS [UV-absorption] - Yes No 0 N N N N N N 30min 1995-10-06 2003-12-31
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 1995-10-20 2003-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1995-10-06 1995-10-19
L1 D1 29 BZN [Benzene] - GC-FID [gas chromatography - flame-ionization detection] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2013-12-31
L1 D1 29 BZN [Benzene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 N N N N N N 30min 2002-01-01 2003-12-31
L1 D1 29 TLN [toluene] - GC-FID [gas chromatography - flame-ionization detection] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2013-07-31
L1 D1 29 TLN [toluene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 N N N N N N 30min 2002-01-01 2003-12-31
L1 D1 29 EBZN [ethylbenzene] - GC-FID [gas chromatography - flame-ionization detection] - Yes Yes 0 N N N N N N 1h 2004-01-01 2013-07-31
L1 D1 29 EBZN [ethylbenzene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 N N N N N N 30min 2002-01-01 2003-12-31
L1 D1 29 OXY [o-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes Yes 0 N N N N N N 1h 2004-01-01 2013-07-31
L1 D1 29 OXY [o-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 N N N N N N 30min 2002-01-01 2003-12-31
L1 D1 29 MXY [m-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes Yes 0 N N N N N N 1h 2004-01-01 2013-07-31
L1 D1 29 MXY [m-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 N N N N N N 30min 2002-01-01 2003-12-31
L1 D1 29 PXY [p-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes Yes 0 N N N N N N 1h 2004-01-01 2013-07-31
L1 D1 29 PXY [p-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 N N N N N N 30min 2002-01-01 2003-12-31
L1 D1 34 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2006-06-30
L1 D1 34 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1996-05-01 2003-12-31
L1 D1 34 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-10-01 2006-06-30
L1 D1 34 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2006-06-30
L1 D1 34 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1996-05-01 2003-12-31
L1 D1 34 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-10-01 2006-06-30
L1 D1 34 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2006-06-30
L1 D1 34 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-01-01 2006-06-30
L1 D1 34 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-01-01 2006-06-30
L1 D1 34 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-01-01 2006-06-30
L1 D1 45 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No No 0 N N N N N N 30min 1997-03-01 2003-12-31
L1 D1 49 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] - No No 0 N N N N N N 1h 2004-01-01 2008-12-31
L1 D1 49 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] - No No 0 N N N N N N 30min 1999-01-01 2003-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No No 0 N N N N N N 30min 1997-03-01 2003-12-31
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1997-03-04 2003-12-31
List of laboratories
Laboratory number 1 (L1) CHMI-Usti n/L AIM
pošt. přihrádka 2
400 11 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2
40011 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz