Information about air quality in the Czech Republic
Measuring programme table
Updated: 2024-10-11 04:49 CEST
Basic data | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | ZOTMA | |||||||||||||||||
Old ISKO number: | 1961 | |||||||||||||||||
Locality: | Otrokovice - mesto | |||||||||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||||||||
Measuring networks: | ||||||||||||||||||
Administrator | ||||||||||||||||||
ENVItech Bohemia s.r.o.
Ovocná 1021/34 161 00 Praha 6 |
Tel.: 736 500 861 | |||||||||||||||||
E-mail: kula@envitech.eu | ||||||||||||||||||
Target of the measuring programme | ||||||||||||||||||
Evaluation of the effect on the population health | ||||||||||||||||||
Cover | ||||||||||||||||||
Hot spot container (air-conditioned) | ||||||||||||||||||
Note | ||||||||||||||||||
Measurements | ||||||||||||||||||
Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | 147 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | - | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 147 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | - | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 147 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | - | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 151 | CO [carbon monoxide] | - | IRABS [IR corel. absorption spectrometry] | - | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 88 | PM 1 [fine particles PM1] | - | OPEL [optoelectronic method] | - | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 88 | PM₂.₅ [fine particles PM2.5] | - | OPEL [optoelectronic method] | - | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 88 | PM₁₀ [particles PM10] | - | OPEL [optoelectronic method] | - | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 35 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 35 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | - | No | Yes | 0 | N | N | N | N | N | N | 10min | 2014-01-01 | |
L1 | D1 | 35 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 35 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | - | No | Yes | 0 | N | N | N | N | N | N | 10min | 2014-01-01 | |
L1 | D1 | 114 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 48 | RAIN [precipitation amount (rain am.)] | - | RAIN [standard rain gauge] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
L1 | D1 | 114 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
List of laboratories | ||||||||||||||||||
Laboratory number 1 (L1) |
ENVItech Bohemia s.r.o.
Ovocná 1021/34 161 00 Praha 6 |
Tel.: 736 500 861 | ||||||||||||||||
E-mail: kula@envitech.eu | ||||||||||||||||||
List of data suppliers | ||||||||||||||||||
Supplier number 1 (D1) |
ENVItech Bohemia s.r.o.
Ovocná 1021/34 161 00 Praha 6 |
Tel.: 736 500 861 | ||||||||||||||||
E-mail: kula@envitech.eu |