0 |
M |
unknown |
unknown |
1 |
M |
SO2 |
Sampling by capture to the solution (West-Geake) |
2 |
M |
SO2 |
unregulated sampling by capture on filter |
3 |
M |
SO2, PM2,5 |
regulated sampling by capture on filter |
4 |
M |
SO2, NO2 |
Radiello, passive sampler |
5 |
M |
NO2, NOx |
sampling by capture in solution (guajacol method) |
6 |
M |
TSP |
unregulated sampling by capture on filter |
7 |
M |
PM10, PM2.5 |
Sven Leckel, SEQ 47/50 |
8 |
M |
PM10, PM2.5 |
Sven Leckel, MVS6 |
9 |
M |
PM10, PM2.5 |
Thermo ESM Andersen, FH 95 SEQ |
10 |
M |
PM10, PM2.5, PAH |
Thermo ESM Andersen, FH 95 KF |
11 |
M |
PM10, PM2.5, PAH |
MCZ, PNS-LVS 16 SEQ |
12 |
M |
PM10 |
Digitel Elektronik, DHA-80 |
13 |
M |
O3, SO2, NO2 |
Ogawa, passive sampler |
16 |
M |
benzene |
Passive sampler |
17 |
A |
SO2 |
Thermo Environmental Instruments (TEI), M43 |
18 |
A |
NO, NO2, NOx |
Thermo Environmental Instruments (TEI), M42 |
19 |
A |
NO, NO2, NOx |
Environnement SA, AC32M |
20 |
A |
CO |
Thermo Environmental Instruments (TEI), M48 |
21 |
A |
CO |
Environnement SA, AC 11M |
22 |
A |
O3 |
Thermo Environmental Instruments (TEI), M49 |
23 |
A |
O3 |
Environnement SA, AC 41M |
24 |
A |
TSP, PM10 |
Verewa, F703 |
25 |
A |
PM10, PM2,5 |
Environnement SA, MP101M |
26 |
A |
PM10, PM2.5 |
Thermo ESM Andersen, FH 62 I-R |
27 |
A |
PM10, PM2.5, PM1 |
Grimm Aerosol Technik, #180 |
28 |
A |
BTX |
Syntech Spectras, GC855 |
29 |
A |
BTX |
Chrompack, CP 7001 |
30 |
A |
BTX |
Environnement SA, VOC71M |
31 |
A |
Hg |
Tekran, 2537 A |
32 |
A |
Hg |
OPSIS AB, Hg200 |
33 |
A |
NH3 |
Thermo Environmental Instruments (TEI), M17 |
34 |
A |
WV, WD |
Vaisala-WAA25, WAW15, WAT12 |
35 |
A |
WV, WD |
WindSonic-Gill Instruments Ltd. |
36 |
A |
WV, WD |
Windobserver Low Temperature-Gill Instruments Ltd. |
37 |
A |
WV, WD, p |
Young model 05103, 61002 |
38 |
A |
WV, WD |
TM, W2t nebo WS 12-H |
39 |
A |
WV, WD |
Observator instruments B.V., OMC 160 |
40 |
A |
T2m |
TM, PT 420 |
41 |
A |
T2m, h |
Commet Systém, NH 421 |
42 |
A |
T2m, h |
Observator instruments B.V., OMC 412 |
43 |
A |
GLRD |
TM, SG 420 |
44 |
A |
GLRD |
Observator instruments B.V., OMC 604 |
45 |
A |
h |
TM, HS 420 |
46 |
A |
p |
ENVItech Bohemia, TS420 |
47 |
A |
radioactivity |
Bauelex s.r.o., Mikro-Gama LB 111 |
48 |
A |
rain |
ENVItech Bohemia, NTM400 |
49 |
A |
rain |
ENVItech Bohemia, PTM250 |
50 |
M |
PM10,PM2.5 |
VAPS model URG-3000K |
51 |
M |
PM10 |
Partisol Sequential Air Sampler model 2025 |
52 |
A |
NBV, NMV, NSV |
SICK |
53 |
A |
SO2 |
API100 |
54 |
A |
NO, NO2, NOx |
API200 |
57 |
A |
CO |
MLU MONITOR LABS, ML 9830 |
58 |
A |
F0025,F0028,F0030,F0035,F0040,F0045,F0050,F0058,F0065,F0070,F0080,F0100,F0130 |
Grimm Aerosol Technik #190 |
59 |
M |
VOC |
Chrompack CP 9000 |
60 |
A |
T2m, h |
Thies Clima KRC 3/5 - b24 |
61 |
A |
CO |
APMA 370, HORIBA APMA370 |
62 |
A |
PM10, PM2,5 |
SHARP 5030 |
63 |
A |
SO2 |
APSA 370, HORIBA APSA 370 |
65 |
A |
NO, NO2, NOx |
APNA 370, HORIBA APNA 370 |
66 |
A |
NBV-in, NBV-out, NBV-s, NEBV-in, NEBV-out, NHV-in, NHV-out, NHV-s, NSV-in, NSV-o |
microwave radar |
67 |
A |
PM2,5 |
BAM 1020 -Met One Instruments |
68 |
A |
SO2 |
Environnement AF 21M |
69 |
A |
NO, NO2, NOx |
Environnement AC 31M |
70 |
A |
SO2 |
Environnemet AF 22M |
72 |
A |
CO |
Environnement SA, AC 12M |
73 |
A |
BZN, TLN |
AMA Instrumennts GC 5000 BTX |
74 |
A |
h, T2m |
Comet system s.r.o., T3313 |
75 |
A |
h, T2m |
Comet system s.r.o., T3319 |
76 |
A |
BC |
Thermo Scientific 5012 MAAP |
77 |
A |
EC,OC |
Sunset Laboratory M4 |
78 |
A |
BZN |
Synspec Alpha 400 |
79 |
A |
Hg |
Tekran 2537B |
80 |
A |
Wv,Wd |
Metek USA-1 AH, Observator OMC 160,Thies Clima |
81 |
A |
p |
Lastem DQA 201, Observator OMC 506, Theodor Fridrichs & Co., Thies Clima |
82 |
A |
T, h |
DeltaOHM, Lastem DMA 580, Observator OMC 402, Thies Clima |
83 |
A |
RAIN |
Lastem DQA 031 |
84 |
A |
GLRD |
Lastem DPA 521, DPA 553 |
85 |
A |
UVB |
Lastem DPA 521 |
86 |
A |
T, h |
HMP 155, radiační kryt DTR503-Vaisala |
91 |
A |
PM1 |
TEOM 5012 |
92 |
A |
F10, F20, F30, F50, F70, F100, F200, UFP1-8 |
SMPS-Tropos + CPC - TSI 3772 |
93 |
A |
SO2 |
Teledyne Advanced Pollution Instrumentation (TAPI), T100 |
94 |
A |
NO, NO2, NOx |
Teledyne Advanced Pollution Instrumentation (TAPI), T200 |
95 |
A |
CO |
Teledyne Advanced Pollution Instrumentation (TAPI), T300 |
96 |
A |
O3 |
Teledyne Advanced Pollution Instrumentation (TAPI), T400 |
97 |
A |
T, h |
Thies HTT Compact |
14 |
A |
SO2 |
Coullograf PW 9700 |
15 |
A |
SO2 |
Kovoslužba coulograf |
56 |
M |
PAHs |
Andersen PS1 |
64 |
M |
VOC |
NILU sampler |
55 |
M |
PM10,PM2,5, PAH, TK |
Sven Leckel, SEQ 47/50 - cooled |
87 |
M |
BZN |
NPL02.air sampler with controlled flow |
88 |
A |
PM10, PM2,5, PM1 |
FIDAS 200- particles of fine fraction monitoring system |
71 |
M |
měření VOC |
Agilent Technologies 7890A |
89 |
A |
F0025,F0028,F0030,F0035,F0040,F0045,F0050,F0058,F0065,F0070,F0080,F0100,F0130 |
Grimm Aerosol Technik #365 |
90 |
A |
WV, WD |
FT 702 |
98 |
A |
PM1, PM2,5, PM10 |
Horiba APDA 372 |
99 |
A |
p, h, T2m |
Thies PT 103 |
100 |
A |
GLRD |
RS - 81 |
101 |
A |
F10T, F20T, F30T, F50T, F70T, F100T, F200T |
TD+SMPS-Tropos + TD + CPC - TSI 3772 |
102 |
M |
BC |
Magee Scientific AE31 |
103 |
A |
H2S |
T100+interní konvertor H2S |
104 |
A |
TRS |
T102+externí konvertor TRS |
105 |
A |
NO, NO2, NOx |
APNA 350E, HORIBA APNA 350E |
106 |
A |
SO2 |
APSA 350E, HORIBA APSA 350E |
107 |
A |
CO |
APMA 350E, HORIBA APMA 350E |
108 |
A |
O3 |
APOA350E, HORIBA APOA 350E |
109 |
A |
PM10 |
TEOM 1400 |
110 |
A |
NO, NO2 NOx |
MLU MONITOR LABS, ML 9841 |
111 |
A |
BZN, TLN |
Syntech Spectras 955 |
112 |
A |
WD, WV, WDm, WVm, veličiny METEK |
uSonic-3 Scientific 3D Ultrasonic Anamometer |
113 |
A |
GLDR |
Kipp&Zonnen CMP6 |
114 |
A |
h,T |
Thies 1.1005.54.000 |
115 |
A |
p |
Vaisala PTB110 |
116 |
A |
SO2 |
Teledyne Advanced Pollution Instrumentation (TAPI), T100U |
117 |
A |
NO, NO2, NOx |
Teledyne Advanced Pollution Instrumentation (TAPI), T200UP |
118 |
A |
NO, NO2, NOx+O3 |
Teledyne Advanced Pollution Instrumentation (TAPI), T204 |
119 |
A |
RAD_A, RAD_B, RAD_C |
NuDET EGM-02-OVP |
120 |
A |
HgO |
PSA 10.525 |
121 |
A |
WD, WV |
Thies ULTRASONIC 2D |
122 |
A |
h, T2m |
COMET system s.r.o. T7511 |
123 |
A |
T, h |
COMET T3100 |
124 |
A |
p |
ENVItech ETBar |
125 |
A |
WV, WD |
WindSonic Option 1, GILL Instruments |
126 |
A |
NO, NO2, NOx |
Horiba APNA370 |
127 |
A |
O3 |
Environement SA,O342e |
128 |
M |
PAH |
Digitel FH77 |
129 |
A |
O3 |
APOA 370, HORIBA APOA 370 |
130 |
M |
F_007_010 - F_200_800 |
SMPS-TSI 3082 + CPC TSI 3750(7,23-470nm) |
131 |
A |
Ptot |
CPC TSI 3750 |
132 |
A |
BC370, BC430, BC470, BC520, BC565, BC590, BC660, BC700, BC880,BC950 |
Met One BC 1054 |
133 |
A |
SO2 |
|
134 |
A |
NO, NO2, NOx |
|
135 |
A |
WV, WD, h, T2m |
kombinované meteočidlo ( WS600-UMB ) |
136 |
M |
POPS |
Digital Elektronik DHA-77 |
137 |
M |
BC370, BC470, BC520, BC590, BC660, BC880, BC950 |
Magee Scientific AE33 |
138 |
M |
TK |
Monitor prachovych castic PM162M |
139 |
A |
PM10, PM2,5 |
OPC Monitor - multikanalovy opticky pocitac castic |
140 |
A |
PAH |
Baghirra Hi 30 AUTO |
141 |
M |
PM10, PM2,5, TK |
Sampler PM10, PM2,5 Baghirra |
142 |
M |
VOC |
Sampler VOC07 Baghirra |
143 |
A |
T, h |
T3113D |
144 |
A |
T, h |
Thies 114A |
145 |
M |
VOC |
AirCheck TOUCH Sample Pump |
146 |
M |
VOC |
Pump Bravo M2 |
147 |
A |
NO, NO2, NOx |
ENVEA Inc. AC 32e |
148 |
A |
h, T |
COMET T3100D |
149 |
A |
O3 |
ENVEA Inc., O342e |
150 |
M |
PAH |
SAM50, BAGHIRRA, s.r.o. |
151 |
A |
CO |
ENVEA Inc.,AC 11M |
152 |
A |
PM10 |
FAG APDA 351E |
153 |
M |
měření VOC |
Agilent Technologies 7890B |
154 |
A |
NO, NO2, NOX |
HORIBA APNA 350 |
155 |
M |
F_007_010 - F_200_800 |
SMPS-TSI 3082 + CPC TSI 3750(10,2-542) |
156 |
A |
NO, NO2, NOx |
ENVEA Inc. AC32M |
157 |
A |
p |
Setra Systems 270 |
158 |
A |
O3 |
Environement SA,O341M |
159 |
M |
UFP1-8 |
SMPS-TSI 3082 + CPC-TSI3750 (10-540 nm) |