Information about air quality in the Czech Republic
Measuring programme table
Updated: 2018-06-07 09:10 CEST
Basic data | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | SKLMA | ||||||||||||||||
Old ISKO number: | 1454 | ||||||||||||||||
Locality: | Kladno-stred mesta | ||||||||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||||||||
Measuring networks: | National air pollution monitoring network | ||||||||||||||||
Administrator | |||||||||||||||||
ČHMÚ - Libuš CLI Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033467 | ||||||||||||||||
Fax:.: | |||||||||||||||||
E-mail: silhavy@chmi.cz | |||||||||||||||||
Target of the measuring programme | |||||||||||||||||
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS) | |||||||||||||||||
Cover | |||||||||||||||||
container (air-conditioned) | |||||||||||||||||
Note | |||||||||||||||||
Stanice je umístěna v panelové zástavbě u parkoviště, asi 50m od stanice je komunikace se slabým provozem. PM10,PM2,5 - sondy Digitel DPM10, DPM2,5. 22.6.2004 došlo k výměně prachoměrů FH621R PM10 a PM2,5 se sondami Digitel za MP101M PM10-Digitel, PM2,5 sonda URG. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||||||||
Measurements | |||||||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
1 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | A | N | A | N | R | N | 1h | 2004-01-01 | |
1 | 1 | PM2,5 [fine particles PM2.5] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | A | N | A | N | N | A | 1h | 2004-01-01 | |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | A | N | A | A | A | A | 1h | 2004-01-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-07-16 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-07-16 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-07-16 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-07-16 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-07-16 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-07-16 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-07-16 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-07-16 | |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | A | N | N | N | N | N | 10min | 2004-10-01 | 2012-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2015-03-23 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2015-03-23 |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2015-03-23 |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-03-05 | 2003-12-31 |
1 | 1 | PM2,5 [fine particles PM2.5] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 2003-03-01 | 2003-12-31 |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | BZN [Benzene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | BZN [Benzene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 2003-10-21 | 2003-12-31 |
1 | 1 | TLN [toluene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | TLN [toluene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 2003-10-21 | 2003-12-31 |
1 | 1 | EBZN [ethylbenzene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | EBZN [ethylbenzene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 2003-11-13 | 2003-12-31 |
1 | 1 | MPXY [m,p-xylene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | MPXY [m,p-xylene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 2003-10-21 | 2003-12-31 |
1 | 1 | OXY [o-xylene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | OXY [o-xylene] | - | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | N | N | N | N | N | N | 30min | 2003-11-13 | 2003-12-31 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 30min | 1999-04-08 | 2003-12-31 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 30min | 1999-04-08 | 2003-12-31 |
1 | 1 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | N | N | N | N | N | N | 30min | 2000-05-24 | 2003-12-31 |
1 | 1 | T [temperature (unspecificated)] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 1999-08-31 |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | No | 0 | N | N | N | N | N | N | 30min | 2000-05-24 | 2003-12-31 |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | No | No | 0 | N | N | N | N | N | N | 30min | 2000-01-01 | 2003-12-31 |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1999-04-08 | 2003-12-31 |
List of laboratories | |||||||||||||||||
Laboratory number 1 | ČHMÚ-CLI TK Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033451 | |||||||||||||||
Fax:.: | |||||||||||||||||
E-mail: rychliks@chmi.cz | |||||||||||||||||
List of data suppliers | |||||||||||||||||
Supplier number 1 | ČHMÚ - Libuš AIM Generála Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033467 | |||||||||||||||
Fax:.: | |||||||||||||||||
E-mail: silhavy@chmi.cz |